Specifications - Desa (V)CB36P(E) Installation And Owner's Operation Manual

4" b-vent decorative vented gas fireplace
Table of Contents

Advertisement

CLEANING AND
MAINTENANCE
Continued
LOGS
• If you remove logs for cleaning, refer to In-
stalling Logs and Glowing Embers, page 18,
to properly replace logs.
• Use a vacuum cleaner to remove any carbon
buildup on logs.
• Replace log(s) if broken. See Replacement
Parts, page 34.
• Replace ember material periodically as needed.
See Replacement Parts, page 34.
(V)CB36N
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS (0.082")
• Ignition: Millivolt
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36P
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS (0.052")
• Ignition: Millivolt
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
ALL MODELS
• Fireplace Dimension HxWxD (Actual size of firebox measurements do not include
nailing flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
• Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)
4
VENTING SYSTEM
Conduct annual inspection of the venting system
following these guidelines:
1. Check areas of venting system that are ex-
2. Remove the vent cap and shine a flashlight
3. Check for evidence of excessive condensation.
4. Inspect joints to verify that no pipe section

SPECIFICATIONS

(V)CB36NE
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Natural
• Orifice Size (Main Burner): #45 DMS (0.082")
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c. (0.87 kPa)
• Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36PE
• Maximum Input Rating: 18,000 Btu/hr
• Gas Type: Propane/LP
• Orifice Size (Main Burner): #55 DMS (0.052")
• Ignition: Electronic
• Manifold Pressure: 10" w.c. (2.5 kPa)
• Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
www.desatech.com
posed to the weather corrosion (rust spots or
streaks and in extreme cases, holes). Have
these items replaced immediately by a quali-
fied service person.
into vent. Remove any foreign material.
Continuous condensation can cause corrosion
of caps, pipes and fittings and can be caused
by having excessive lateral runs, too many
elbows or exterior portions of the system being
exposed to cold weather.
or fitting has been distributed and loosened.
Check mechanical supports such as wall straps
for rigidity.