IBM 419452u - Servers System X3250 M2 Xeon 3.0ghz Installation Manual page 56

Installation guide
Hide thumbs Also See for 419452u - Servers System X3250 M2 Xeon 3.0ghz:
Table of Contents

Advertisement

42
IBM System x3250 M2 Types 4190 and 4194: Installation Guide
Table 4. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must
be performed only by a trained service technician.
Error code
Description
I9990305
An operating system was not
found.
I9990650
AC power has been restored.
Action
1. Make sure that a bootable
operating system is installed.
2. Run the hard disk drive
diagnostic tests.
3. Reseat the following
components:
a. Hard disk drive
b. CD or DVD drive and
cables
c. (Trained service technician
only) System board
4. Replace the components listed
in step 3 one at a time, in the
order shown, restarting the
server each time.
1. Check the power cables.
2. Check for interruption of the
power supply.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3250 m241904194

Table of Contents