SPECIFICATIONS
At LOW setting
• Output Rating - 65,000 Btu/Hr (61,000 kJ/Hr)
• Fuel Consumption - 0.7 Gal/Hr (2.6 Litres/Hr)
• Fuel Consumption - 3.0 lb/Hr (1.36 kg/Hr)
At MED setting
• Output Rating - 85,000 Btu/Hr (80,570 kJ/Hr)
• Fuel Consumption - 0.93 Gal/Hr (3.5 Litres/Hr)
• Fuel Consumption - 3.9 lb/Hr (1.8 kg/Hr)
At HIGH setting
• Output Rating - 100,000 Btu/Hr (94,800 kJ/Hr)
• Fuel Consumption - 1.1 Gal/Hr (4.2 Litres/Hr)
• Fuel Consumption - 4.6 lb/Hr (2.1 kg/Hr)
For all settings
• Propane Vapor Fuel Only
• Supply Pressure To Regulator:
Minimum (for purposes of input adjustment)
10 psi (69 kPa)
Maximum - Tank Pressure
• Regulator Outlet Pressure - Factory Preset
• Manifold Pressure - 10" (25.4 cm) WC
• Hot Air Output (CFM Approx) - 475 (13.45 m)
• Motor - 3,200 RPM, 1/10 HP
• Electric Input - 120 V/60 Hz
• Amperage - 2.9
• Ignition - Continuous
• Ignitor Gap - 0.13"/0.15" (3.3/3.8 mm)

TECHNICAL SERVICE

You may have further questions about this heater.
If so, contact DESA Heating Productsʼ Technical
Service Department at 1-866-672-6040. When
calling, please have your model and serial numbers
of your heater ready.
You can also visit DESA Heating Productsʼ Techni-
cal Service web site at www.desatech.com.
12

REPLACEMENT PARTS

WARNING: Use only original
replacement parts. This heater
must use design-specific parts.
Do not substitute or use generic
parts. Improper replacement
parts could cause serious or fa-
tal injuries. This will also protect
your warranty coverage for parts
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they
canʼt supply original replacement part(s), call
DESA Industries at 1-905-826-8010.
When calling DESA Industries, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date
In most cases, we will ask you to return the part
to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If
they canʼt supply original replacement part(s),
call DESA Industriesʼ Parts Department at
1-905-826-8010.
When calling DESA Industries, have ready:
• model number of your heater
• the replacement part number
Purchase accessories and parts from your nearest
dealer or service center. If your dealer or service
center can not supply an accessory or part, call DESA
Industriesʼ Parts Department at 1-905-826-8010. You
can also write to the address listed on the back page
of this manual.
FUEL GAS CONNECTOR - LPA4020
Connects regulator to all standard propane tanks.
U.L. and A.G.A. listed.
www.desatech.com