Service Procedures - Desa RCLP155B Owner's Manual

Desa owner's manual propane construction heater rclp155b
Table of Contents

Advertisement

Available languages

Available languages

CANADIAN RCLP155B
PROPANE CONSTRUCTION HEATER
SERVICE
PROCEDURES
WARNING: Never service
heater while it is plugged in, con-
nected to propane supply, oper-
ating, or hot. Severe burns and
electrical shock can occur.
UPPER SHELL REMOVAL
1. Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.
2. Lift or slide upper shell off.
3. Remove fan guard.
FAN
IMPORTANT: Remove fan from motor
shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.
1. Remove upper shell (see above).
2. Use 1/8" hex wrench to loosen setscrew
which holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened
with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Make sure
setscrew is touching back of flat sur-
face on motor shaft (see Figure 8).
7. Place setscrew on flat of shaft. Tighten
setscrew firmly 4.5 to 5.6 N-lb (40-50
in-lb).
8. Replace fan guard andupper shell.
IGNITOR
1.
Make sure gap between ignitor electrode
and burner nozzle is 3.3/3.8 mm (.13/
.15 in). Access ignitor electrode from in-
side combustion chamber. No other
maintenance is needed for ignitor.
Figure 5 - Upper Shell Removal
Figure 6 - Fan Removal
Fan
Setscrew
Motor shaft
FAN
LP-PFA/P 023
Figure 7 - Fan, Motor Shaft, and Setscrew
Location
6
Fan
Hub
FAN CROSS SECTION
Figure 8 - Fan Cross Section
Motor
Fan
Motor
Shaft
Setscrew
LP-PFA/P 013
103909