Operations (Step 6 Operations with a Web Browser)
6-4 Settings with a Web Browser (4. Alarm Settings)
Alarm Setting Window:
http://******/alarm-e.html (****** represents the URL of VN-C11.)
This section describes the setting of actions of VN-C11 when an alarm signal has been received.
Item
Alarm In
Alarm 1 and 2
On/Off
Alarm Out
Relay Alarm
On/Off
Relay Alarm Setting
Alarm Out
Alarm Out
On/Off
Momentum
Value
Power on Init
Caution
• Perform the output setting appropriately according to the equipment to which signals are
sent.
• When the alarm setting is complete, check whether the alarm functions are working prop-
erly.
70
Click [Apply] to update the settings.
Specifies the action when an alarm signal has been received.
Specifies the action when an alarm signal has been input to
[Alarm 1] and/or [Alarm 2].
Select [On] if the alarm terminals [Alarm 1] and/or [Alarm 2]
are to be used. If not to be used, select [Off].
If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.
Sets the relay alarm function, which is activated when two
alarms are successively received within a certain period of
time.
Select whether to enable or disable the relay alarm function.
Sets the sequence and interval of alarm input.
If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.
Select [On] for alarm signals to be output to the [ALARM
OUTPUT] terminal located on the rear panel.
Sets the duration for sending alarm output signals.
Sets whether to output high or low signals for alarm output.
If [Yes] is selected, the alarm signal, which was set upon
power connection, is output once.