SAFETY INFORMATION
Continued
5. Always run heater with plaque control knob at the
1, 2, 3 or 4 locked positions. Never set control knob
between locked positions. Poor combustion and
higher levels of carbon monoxide may result.
6. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater if
not enough fresh air is available. See Air for
Combustion and Ventilation, page 5.
7. Keep all air openings in front and bottom of
heater clear and free of debris. This will insure
enough air for proper combustion.
8. If heater shuts off, do not relight until you
provide fresh, outside air. If heater keeps
shutting off, have it serviced.
9. Do not run heater
where flammable liquids or vapors are
used or stored
under dusty conditions
10. Do not use heater if any part has been under
water. Immediately call a qualified service
technician to inspect the room heater and to
replace any part of the control system and any
gas control which has been under water.
11. Turn off and unplug heater and let cool before
servicing. Only a qualified service person
should service and repair heater.
12. Operating heater above elevations of 4,500
feet could cause pilot outage.
13. To prevent performance problems, do not use pro-
pane/LP fuel tank of less than 100 lbs. capacity.
14. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
15. Provide adequate clearances around air
openings.

LOCAL CODES

Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
4
www.desatech.com
Front Panel
Heater Cabinet
Grill
Guard
113052-01D