Troubleshooting; Technical Service; Accessory - Desa RCLP155AT Owner's Manual

Desa owner's manual construction forced air heater rclp155at
Table of Contents

Advertisement

Available languages

Available languages

WARNING: Never service heater while it is plugged in, connected
to propane supply, operating or hot. Severe burns and electrical
shock can occur.
OBSERVED FAULT
Fan does not turn when heater is
plugged in
Heater will not ignite
Heater shuts down while run-
ning
WARNING: Use
only in areas free of
high dust content.

TECHNICAL SERVICE

You may have further questions about this heater.
If so, contact DESA Heating Productsʼ Technical
Service Department at 1-866-672-6040. When
calling, please have your model and serial numbers
of your heater ready.
You can also visit DESA Heating Productsʼ Techni-
cal Service web site at www.desatech.com.
8

TROUBLESHOOTING

POSSIBLE CAUSE
1. No electrical power to heater
2. Fan hitting inside of heater
shell
3. Fan blades bent
4. Defective motor
1. User did not follow installa-
tion or operation instructions
properly
2. No spark at ignitor. See Ig-
nitor, page 7. If you see spark
at ignitor, have heater serviced
by qualified service person. If
no spark seen:
A) Loose or disconnected
ignitor wire
B) Wrong spark gap
C) Bad ignitor electrode
1. Propane supply may be inad-
equate
2. High surrounding air tem-
perature causing thermal limit
device to shut down heater.
3. Restricted air flow
4. Damaged fan
5. Excessive dust or debris in
surrounding area
www.desatech.com
REMEDY
1. Check voltage to electrical
outlet. If voltage is good, check
heater power cord for breaks
2. Adjust motor/fan mount to
keep fan from hitting inside of
heater shell. Bend fan mount
if necessary
3. Replace fan. See Fan, page 6
4. Replace motor
1. Repeat installation and operation
instructions. See Installation,
page 4 and Operation, page 5
2. A) Check ignitor wire. Tighten
or reattach loose ignitor wire.
B) Assure gap between ignitor
electrode and target plate is
0.13"0/.15" (3.3/3.8 mm). Do
not bend electrode. Doing so
may cause it to break
C) Replace ignitor electrode
1. A) Refill tank
B) Provide additional and/or
larger tanks. See Propane
Supply, page 3
2. This can happen when running
heater in temperatures above
85° F (29˚ C). Run heater in
cooler temperatures
3. Check heater inlet and outlet.
Remove any obstructions
4. Replace fan. See Fan, page 6
5. Clean heater. See Mainte-
nance, page 6

ACCESSORY

Purchase accessories and parts from your nearest
dealer or service center. If your dealer or service
center can not supply an accessory or part, call
DESA Industriesʼ Parts Department at 1-905-826-
8010. You can also write to the address listed on
the back page of this manual.
THERMOSTAT - HA1210
109005-01C

Advertisement

Table of Contents
loading

Table of Contents