Desa GWN20TA Safety Information And Installation Manual page 16

Desa unvented (vent-free) blue flame gas heater safety information and installation manual gwn20ta, gwp20ta, gwn30ta, gwp30ta, wmn20a, wmp20a
Table of Contents

Advertisement

oPeRATING HeATeR
Continued
WARNING: Always operate
manual control heaters at the
locked positions. Operation
between these positions may
create a possible health hazard
if used in a poorly ventilated
room. Read owner's manual for
complete instructions.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Figure 21 - Pilot (actual pilot may vary)
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
PILOT position.
16
Thermocouple
Ignitor Electrode
Pilot Burner
www.desatech.com
THERMOSTAT CONTROL
The thermostatic control used on these
models differs from standard thermostats.
Standard thermostats simply turn on and off
the burner. The thermostat used on this heater
senses the room temperature. The thermostat
adjusts the amount of gas flow to the burner.
This increases or decreases the burner flame
height. At times the room may exceed the
set temperature. If so, the burner will shut
off. The burner will cycle back on when room
temperature drops below the set temperature.
The control knob can be set to any heat level
between 1 and 5. Selecting the 5 setting will
cause the burner to remain fully on without
modulating down in most cases.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your heater will let you determine your own
comfort levels.
1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 7 under Lighting
Instructions, page 15.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
to the
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, page 15.
5. Replace front panel.
to the
OPERATION
MANUAL LIGHTING
PROCEDURE
119344-01B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwp20taGwp30taGwn30taWmn20aWmp20a

Table of Contents