Local Codes; Unpacking; Product Features; Installing Heater - Desa Comfort Glow CGR35NA Owner's Operation And Installation Manual

Desa owner's operation and installation manual vented natural gas heaters cgr65bna, cgr65na, cgr50bna, cgr50na, cgr35na
Table of Contents

Advertisement

LOCAL CODES

UNPACKING

PRODUCT
FEATURES
INSTALLING
HEATER
6
Install and use heater with care. Follow all local codes. In the absence of local
codes, use the latest edition of the following:
• National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 *
• National Electrical Code ANSI/NFPA 70 *
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other
sources to light heater.
Thermostatic Heat Control
This heater has a thermostat sensing bulb and a control valve. This results in the
greatest heating comfort. This can also result in lower gas bills.
A qualified service person must install heater and
venting system. Have them inspect heater before use
and at least annually. Follow all local codes.
This heater must be electrically grounded if equipped with
blower. Follow all local codes. In the absence of local
codes, follow the National Electric Code, ANSI/NFPA 70.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater.
Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have all items below.
• piping (check local codes)
• sealant (resistant to propane gas)
• manual shutoff valve *
• ground joint union
• test gauge connection * (see
Figure 7, page 12)
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an
acceptable alternative to test gauge connection. Purchase the optional A.G.A.
design-certified manual shutoff valve from your dealer. See Accessories, page 37.
1430 Broadway
New York, NY 10018
Batterymarch Park
Quincy, MA 02269
WARNING
WARNING ICON
G 001
NOTICE
• sediment trap
• tee joint
• pipe wrench
• venting materials
100792