Desa Comfort Glow CGP10RLA Owner's Operation And Installation Manual

Desa owner's operation and installation manual infrared vent-free propane/lp gas heater cgp10rla

Advertisement

Quick Links

INFRARED VENT-FREE PROPANE/LP GAS HEATER
OWNER'S OPERATION AND INSTALLATION MANUAL
CGP10RLA
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it
is installed. Provisions for ad-
equate combustion and venti-
lation air must be provided.
Refer to Air For Combustion
and Ventilation section on page
4 of this manual.

Advertisement

Table of Contents
loading

Summary of Contents for Desa Comfort Glow CGP10RLA

  • Page 1 INFRARED VENT-FREE PROPANE/LP GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUAL CGP10RLA WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Safety Information

    PROPANE/LP GAS HEATER SAFETY INFORMATION WARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, and car- bon monoxide poisoning.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Front Panel Figure 1 - Vent-Free Propane/LP Gas Heater LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
  • Page 4: Air For Combustion And Ventilation

    PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 5 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6: Ventilation Air

    PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12"...
  • Page 7: Locating Heater

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater.
  • Page 8 PROPANE/LP GAS HEATER INSTALLATION Continued Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater. Attaching to Wall Stud Method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit.
  • Page 9: Connecting To Gas Supply

    INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane/LP supply.
  • Page 10: Operating Heater

    PROPANE/LP GAS HEATER INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Page 11 OPERATING HEATER Continued LIGHTING INSTRUCTIONS 1. STOP! Read the safety information page 10, column 3. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas.
  • Page 12: Inspecting Burner

    PROPANE/LP GAS HEATER INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed and control knob is pressed in and turned to the PILOT...
  • Page 14 PROPANE/LP GAS HEATER TROUBLESHOOTING Continued OBSERVEDPROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is lit or shut off White powder residue forming within burner box or on adjacent walls or furniture POSSIBLE CAUSE...
  • Page 15 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 16: Specifications

    Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, either contact your nearest Parts Central (see page 17) or call DESA International’s Parts Department at 1-800- 972-7879 for referral information. You can also write to the address listed on the back page of this manual.
  • Page 17: Parts Centrals

    PARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441...
  • Page 18 PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10RLA ODS/PILOT 104275...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 16 of this manual. CGP10RLA PART NUMBER 098304-01 099467-07 099318-03 101108-01 099469-02 M15823-37 099059-03 098514-01 098594-01 099884-02...
  • Page 20: Warranty Information

    COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.