iNSTALLATiON OPTiONS

Thermador Pro Grand® Ranges feature a bold,
professional design and a commercial-depth of
27-inches. These ranges can be installed in a wall
or island installation.
BAckGuARD
48-inch Thermador Pro Grand Ranges require an
accessory backguard. Choices include a 12-inch low
backguard or a 22-inch high shelf backguard. Either
backguard must be attached before sliding the range
into the nal installed position. An Island Trim is
available for covering the backguard mounting flanges
for island installations, where there is a minimum of 12"
of horizontal clearance behind the island trim.
cAuTiON:
To avoid possible burn or re hazard, a
backguard designed speci cally for this range must
be installed whenever the range is used.
NATuRAL GAS OR LP
Thermador All-Gas Pro Grand Ranges are shipped by
the factory to operate on natural gas or LP. Be sure to
order the correct fuel-type and verify that the type of
gas being used at the installation site matches the type
of gas used by the appliance.
iMPORTANT
We strongly recommend that a Thermador
Professional Wall or Island Hood or Custom Insert
be installed with all Thermador Pro Grand Ranges.
Downdraft ventilation should not be used. Do not
install a microwave-hood combination above the
cooktop, as these types of units do not provide the
proper ventilation and are not suitable for use with
Thermador Pro Grand Ranges. Refer to the Ventilation
section or www.Thermador.com for a complete
selection of Professional ventilation options, blowers,
and accessories.
Due to the 27-inch commercial-depth of Pro Grand
Ranges, the PH Professional Series Wall Hoods or
Professional Series Custom Inserts would provide the
appropriate depth from the wall to correspond to
these ranges.
Models: PRG486EDG / PRL486EDG, PRG486EDPG / PRL486EDPG
48-INCH CuTOuT AND RANGE DIMENSIONS
* 30" minimum clearance above cooking surface to
non-combustible surface. Minimum clearance above
cooking surface to combustible surface is 36".
** 3" minimum clearance from cooking surface to
combustible side walls.
Note: Most hoods contain combustible components that
must be considered when planning the installation.
measurement in inches
measurement in inches
1.800.735.4328 | THERMADOR.COM
PRO
GRAND®
RANGES
Gas and Electric connections