Mantel Clearances; Floor Clearances - Desa CFS18PRA Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) propane/lp gas log heater cfs18pra, vs18pra, vs24pra, vs30pra
Table of Contents

Advertisement

INSTALLATION
Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet clearances
listed in Figure 6 you will need a hood.
Determining Minimum Mantel
Clearance
If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).
Determining Minimum Mantel
Clearance When Using a Hood
If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level,
you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).
B. If combustible materials are less than
14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).
104417
10"
8"
6"
1 /2
2
Minimum Non-
Combustible
Material
Minimum Non-
Combustible
Material Height
Figure 6 - Minimum Mantel Clearances Without Using Hood
12"
10"
8"
6"
1 /2
2
Minimum Non-
Combustible
Material
Hood
Hood
(GA6050, GA6052,
(GA6050, GA6052)
or GA6053)
Figure 7 - Minimum Mantel Clearances When Using Hood
14"
Min.
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
9
OWNER'S MANUAL
Mantel Shelf
"
(A)
12"
18"
20"
22"
8"
14"
16
3 / 4
"
18
1 / 2
"
Distances to
Underside of
Mantel
Mantel Shelf
"
8"
12"
15"
18"
Min.
Distances to
Underside of
Mantel
Combustible
Material
Noncombustible
Material
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Set
24"
24"/30" Models
20"
18" Model
Top of Fireplace
Opening
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Sets
20"
18", 24",
& 30" Models
Top of Fireplace
Opening
Hearth
Hearth
Combustible
Combustible
Material
Material
5"
5"
Min.
Min.
Continued

Advertisement