Local Codes; Product Identification; Product Features; Piezo Ignition System - Desa Comfort Glow CCL3924NR Owner's Operation And Installation Manual

Premium aged split oak and yellow flame unvented (vent-free) natural gas log heaters
Table of Contents

Advertisement

SAFETY
INFORMATION
Continued
14. Turn heater off and let cool before ser-
vicing, installing, or repairing. Make sure
the remote selector switch is in the OFF
position. Only a qualified service person
should install, service, or repair heater.
15. Make sure the remote selector switch is
in the OFF position when you are away
from home for long periods of time.
16. This heater must not be connected to
any external electrical source.
17. Operating heater above elevations of
4,500 feet may cause pilot outage.
PRODUCT
IDENTIFICATION
Crossover Log
Front Log
Optional
Remote
Control
Piezo Ignitor
Optional Selector Switch
Flame Adjustment Knob
Figure 1 - Yellow Flame Vent-Free Gas Log Heater Shown (Logs May Vary by Model)
107553

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs
are required, thermostat operation is not
permitted.
Control Knob
OWNER'S MANUAL
UNPACKING
1.
2. Remove all protective packaging ap-
3. Check all items for any shipping dam-
PRODUCT
FEATURES
OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a
Back Log
vent or up a chimney. Heat is generated by
realistic dancing, yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. This heater may also be operated as
a vented decorative (ANS Z21.60) product
by opening flue damper (non-thermostat
Burner
models only).
SAFETY PILOT
Middle Log
This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough
Base Grate
fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
For more information, visit www.desatech.com
3
CAUTION: Do not remove the
metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.
Remove logs and heater base assem-
bly from carton. Note: Do not pick up
heater base assembly by burners. This
could damage heater. Always handle
base assembly by grate.
plied to logs and heater for shipment.
age. If damaged, promptly inform
dealer where you bought heater.

Hide quick links: