30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
5.B
Four Conductor Wire Connection
to the Range
1. Remove the screws at the lower end of the rear wire
access cover or panel, then remove the access cover or
lift the lower part of the access panel to expose range
terminal connection block (Fig. 7 or 8).
2. Remove the three loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the power supply
cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground
strap was removed (see Figure 10).
5. Connect the neutral wire of the power supply cord to
the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals.
Match terminal and power supply wires by color.
6. Replace the 3 nuts on the terminal block (see Figure
10).
7. Replace the rear access panel using the screws
removed on step 1.
Figure 10
Four Conductor or Wire Connection to Range
(Model with Electric Oven and Gas Cooktop)
6.
Direct Electrical Connection to
the Circuit Breaker, Fuse Box or
Junction Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or non me-
tallic sheathed copper cable (with grounding wire). Supply
a U.L. listed strain-relief at each end of the cable. At the
appliance end, the cable goes through the Direct Con-
nection Hole (see Figure 10) on the Cord Mounting Plate.
Wire sizes (copper wire only) and connections must
conform to the rating of the appliance.
You may not ground the oven
through the neutral (white) wire if oven is used
in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicle, or where local
codes do not permit grounding through the neutral
(white) wire. When grounding through the neutral
(white) wire is prohibited, you must use a 4-wire
power supply cable. See Section 6B. Failure to heed
this warning may result in electrocution or other
serious personal injury.
6.A
Three Conductor Wire
Connection to the Junction Box
Where local codes permit connecting the appliance
cable ground wire to the power supply cable
neutral (white) wire (see Figure 11).
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
Connect appliance and power supply cable wires as
shown in figure 11.
Cable from Power Supply
White Wire
(Neutral)
Red Wires
Ground Wire
(Bare or Green Wire)
Cable from appliance
Figure 11 - 3-WIRE GROUNDED JUNCTION BOX
Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
6
Black
Wires
Junction
Box
White Wire
(Neutral)
U.L.-Listed
Conduit Connector
(or CSA listed)