Desa BLUE FLAME BLUE FLAME VENT-FREE NATURAL GAS HEATER Operation And Installation Manual page 13

Blue flame vent-free natural gas heater 6000 btu manually controlled models
Table of Contents

Advertisement

TROUBLE-
SHOOTING
Continued
OBSERVED PROBLEM
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during combustion
Yellow flame during burner combustion
Slight smoke or odor during initial opera-
tion
Heater produces a whistling noise when
burner is lit
Heater produces a clicking/ticking noise
just after burner is lit or shut off
103113
POSSIBLE CAUSE
1. Burner orifice is clogged
2. Burner orifice diameter is too small
3. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice is clogged
1. Burner orifice is clogged or damaged
2. Inlet gas pressure is too low
3. Burner damaged
4. Gas regulator defective
1. Not enough air
2. Inlet gas pressure is too low
3. Gas regulator defective
1. Residues from manufacturing processes
1. Turning control knob to HIGH position
when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
1. Metal expanding while heating or con-
tracting while cooling
13
OWNER'S MANUAL
REMEDY
1. Clean burner orifice (see Cleaning and
Maintenance, page 11) or replace burner
orifice
2. Replace burner orifice
3. Contact local natural gas company
1. Contact local natural gas company
2. Clean burner orifice (see Cleaning and
Maintenance, page 11) or replace burner
orifice
1. Clean burner orifice (see Cleaning and
Maintenance, page 11) or replace burner
orifice
2. Contact local natural gas company
3. Replace burner
4. Replace gas regulator
1. Check burner for dirt and debris. If
found, clean burner (see Cleaning and
Maintenance, page 11)
2. Contact local natural gas company
3. Replace gas regulator
1. Problem will stop after a few hours of
operation
1. Turn control knob to LOW position and
let warm up for a minute
2. Operate burner until air is removed from
line. Have gas checked by local natural
gas company
3. Observe minimum installation clear-
ances (see Figure 4, page 6)
4. Clean burner (see Cleaning and Main-
tenance, page 11) or replace burner ori-
fice
1. This is common with most heaters. If
noise is excessive, contact qualified ser-
vice person
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vn600bCfn600b

Table of Contents