Desa BLP100 Owner's Manual

Propane construction forced air heater

Advertisement

For more information, visit www.desatech.com
For more information, visit www.desatech.com
Models
BLP100
REM100LP
Variable 65,000,
85,000, and 100,000
Btu/Hr
IMPORTANT: Read and understand this manual before assembling, starting, or servicing
heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

TABLE OF CONTENTS

SAFETY INFORMATION ............................................................ 2
PRODUCT IDENTIFICATION ..................................................... 3
UNPACKING ............................................................................... 3
THEORY OF OPERATION ......................................................... 3
PROPANE SUPPLY .................................................................... 4
INSTALLATION ........................................................................... 4
VENTILATION ............................................................................. 4
OPERATION ............................................................................... 5
STORAGE ................................................................................... 5
MAINTENANCE .......................................................................... 5
Save this manual for future reference.
Save this manual for future reference.
PROPANE CONSTRUCTION
FORCED AIR HEATER
OWNER'S MANUAL
TROUBLESHOOTING ................................................................ 6
SERVICE PROCEDURES .......................................................... 7
SPECIFICATIONS ...................................................................... 9
WIRING DIAGRAM ..................................................................... 9
ACCESSORIES .......................................................................... 9
TECHNICAL SERVICE ............................................................. 12
REPLACEMENT PARTS .......................................................... 12
OWNER'S REGISTRATION FORM .......................................... 13
WARRANTY INFORMATION ...................................... Back Cover

Advertisement

Table of Contents
loading

Summary of Contents for Desa BLP100

  • Page 1: Table Of Contents

    For more information, visit www.desatech.com For more information, visit www.desatech.com Models BLP100 REM100LP Variable 65,000, 85,000, and 100,000 Btu/Hr IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
  • Page 2: Safety Information

    SAFETY INFORMATION SAFETY INFORMATION WARNINGS WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm. WARNING: FIRE, BURN, INHALATION, AND EX- PLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARD- BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUC- TIONS.
  • Page 3: Product Identification

    SAFETY INFORMATION Continued • To prevent injury, wear gloves when handling heater. • Never attach duct work to heater. • Do not alter heater. Keep heater in its original state. • Do not use heater if altered. • Turn off propane supply to heater when not in use. •...
  • Page 4: Propane Supply

    PROPANE SUPPLY INSTALLATION VENTILATION PROPANE SUPPLY Propane gas and propane tank(s) are to be furnished by the user. Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and the Propane Instal- lation Code CAN/CGA B149.2.
  • Page 5: Operation

    OPERATION WARNING: Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ven- tilation before running heater. WARNING: Review and understand the warnings in the Safety Information section, page 2.
  • Page 6: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Note: For additional help, visit DESA Heating Products’ Technical Service web site at www.desatech.com. OBSERVED FAULT Fan does not turn when heater is plugged in. Heater will not ignite Heater shuts down while running. For more information, visit www.desatech.com For more information, visit www.desatech.com...
  • Page 7: Service Procedures

    SERVICE PROCEDURES WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur. MOTOR 1. With heater on its side, remove base tray. 2. Access ground screw through underside of heater base. Re- move ground screw.
  • Page 8 SERVICE PROCEDURES SERVICE PROCEDURES Continued Remove motor, motor mount, and fan (see Motor, steps 1 through 8, page 7). 2. Clean fan using soft cloth moistened with kerosene or solvent. 3. Dry fan thoroughly. 4. Replace fan on motor shaft. Make sure setscrew is touching back of flat surface on motor shaft (see Figure 8).
  • Page 9: Specifications

    If your dealer or service center can not supply an accessory or part, either contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or call DESA Heating Products at 1-866-672-6040 for referral information. You can also...
  • Page 10: Illustrated Parts Breakdown And Parts List

    ILLUSTRATED PARTS BREAKDOWN Models BLP100 and REM100LP ILLUSTRATED PARTS BREAKDOWN MODELS BLP100 REM100LP For more information, visit www.desatech.com For more information, visit www.desatech.com 102370-01K...
  • Page 11 Tradename Decal, REM100LP 105350-09 Operation Decal 105351-01 Warning Decal 102599-01 Electrical Decal 111632-05 Model Data Decal LPA3100 Regulator and Hose Assembly LPA1000 10’ Hose Assembly LPA2150 Regulator ** Not a field replacement part. PARTS LIST Models BLP100 and REM100LP QTY.
  • Page 12: Technical Service

    TECHNICAL SERVICE REPLACEMENT PARTS TECHNICAL SERVICE You may have further questions about this heater. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672- 6040. When calling please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ Technical Service web site at www.desatech.com.
  • Page 13: Owner's Registration Form

    First Name: Address: City: Phone: ( Please answer the following questions to register your product with DESA Heating Products: 1. Who will heater be used by? Individual 2. Will you use your heater in more than one location? 3. Where will the product be used? (You may select more than one.)
  • Page 14 Postage Required 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 TAPE...
  • Page 15 OTHER OUTDOOR HEATING PRODUCTS PROPANE/LP FORCED AIR HEATERS PROPANE/LP CONVECTION HEATERS PORTABLE KEROSENE/DIESEL FORCED AIR HEATERS PROPANE/LP TANK TOP HEATERS PROPANE/LP AND NATURAL GAS GARAGE HEATERS PROPANE/LP PROPANE/LP AND NATURAL PATIO HEATERS GAS CHIMENEAS...
  • Page 16: Warranty And Repair Service

    Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA Heating Products will repair or replace the heater without charge.