Problem 11
The Adaptec SCSI RAID controller
drive.
Solution 11
This typically happens when a drive that is attached to an Adaptec SCSI RAID
controller has been formatted with a sector size other than 512 bytes. Use SMOR to
reformat the drive with 512-byte sectors. This can also occur if the drive is the 9th or
higher logical drive attached to the controller.
IMPORTANT: Using SMOR to set Bootable Devices to Disabled as in the previous problem
will result in the same symptoms. If you require access to disk drives connected to the Adaptec
SCSI RAID controller during the boot process, change Bootable Devices to Normal.
Problem 12
Although the SCSI devices can be accessed by the Adaptec SCSI RAID controller,
the fault LEDs on the devices in a RAIDstation storage cabinet do not flash during
boot-up and the Adaptec SCSI RAID controller does not detect drive swaps or
cabinet failures.
Solution 12
These symptoms indicate that the RAIDstation storage cabinet status signals are not
being properly received by the Adaptec SCSI RAID controller.
For SAF-TE or SES: this can result from a failed enclosure monitoring module in the
subsystem cabinet.