EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN DO 1500 Installation And User Manual

Data acquisition software bench dissolved oxygen meter
Hide thumbs Also See for CYBERCOMM PRO FOR CYBERSCAN DO 1500:

Advertisement

Quick Links

CyberComm Pro 2.4
Data Acquisition Software
Installation & User Guide
CyberScan DO 1500
Bench Dissolved Oxygen Meter
68X292341
Rev.0 01/04
Technology Made Easy ...

Advertisement

Table of Contents
loading

Summary of Contents for EUTECH INSTRUMENTS CYBERCOMM PRO FOR CYBERSCAN DO 1500

  • Page 1 CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter 68X292341 Rev.0 01/04 Technology Made Easy ...
  • Page 3 CyberComm Pro version via our website at www.eutechinst.com/cybercomm- software.htm Eutech Instruments reserves the rights to change, make improvement and modify specifications without prior notice and cannot accept any responsibility for damage or malfunction to the instrument caused by improper use.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS 1 Data Acquisition in windows Version The CyberComm DAS Package System Requirements 1.2.1 Setting the Communication Parameters 2 Installation of CyberComm Data Acquisition Software (DAS) Loading of CD-ROM User Name and Organisation Entry Splash Screen 3 Cybercomm Pro Main Menu Communication Settings (File) Data Log Options (File) Connect to Meter (File)
  • Page 5: Data Acquisition In Windows Version

    Instruction Manual CyberComm DO 1500 DATA ACQUISITION IN WINDOWS VERSION The CyberComm DAS Package The CyberComm Data Acquisition Software (DAS) package is a user-friendly data acquisition package that provides a convenient way to capture data for future analysis. This CyberComm Pro is only able to run on ©...
  • Page 6: Installation Of Cybercomm Data Acquisition Software (Das)

    Instruction Manual CyberComm DO 1500 INSTALLATION OF CYBERCOMM DATA ACQUISITION SOFTWARE (DAS) Loading of CD-ROM See Figure 1. Before running the program, check that the CyberScan DO1500 meter is properly connected to the computer. It is preferable to connect to either one of the COM (serial) ports available on a computer. Note the number of the COM port that you have connected to the meter as this will be required in setting up the CyberComm DAS later.
  • Page 7: User Name And Organisation Entry

    Instruction Manual CyberComm DO 1500 User Name and Organisation Entry The CyberComm program (as below) prompts you to enter the name of the user and organization. Figure 2: CyberComm Pro Installation/ User Information See Figure 2. Follow the instruction in the subsequent menu for your desired location of this file to be saved. Make relevant changes until the setup is completed (shown below).
  • Page 8: Splash Screen

    Instruction Manual CyberComm DO 1500 Splash Screen See Figure 4. Upon clicking the Finish button, a splash screen pops up (shown below). The meter’s communication protocol setting i.e. baud rate, parity and stop bits must be properly set before you power the meter on. DO NOT press any key on the meter while the program is running.
  • Page 9: Cybercomm Pro Main Menu

    Instruction Manual CyberComm DO 1500 CYBERCOMM PRO MAIN MENU Figure 5: CyberComm Main Menu See Figure 5. Select Communications Settings and set the appropriate requirements before connecting the meter. Communication Settings (File) See Figure 6. To make changes, use the drop-down menu of each parameter to set to desired values to match the meter’s settings.
  • Page 10: Data Log Options (File)

    Instruction Manual CyberComm DO 1500 Data Log Options (File) See Figure 7. a) Time between successive readings (1-3600 sec). Default is 10 sec. Select the time lag preferred between each successful reading using the arrow keys. b) Length of Time to Capture Data. Default is 0 min. (0= indefinitely, units = min) Select the total length of time preferred to capture data using the arrow keys.
  • Page 11: Main Window (After Connecting Meter To Computer)

    Instruction Manual CyberComm DO 1500 MAIN WINDOW (AFTER CONNECTING METER TO COMPUTER) CyberComm Professional Manuals (Help) See Figure 8 and 9. The main menu appears with the File and Help drop down menus, each having a list function settings shown below.
  • Page 12: File Options (File)

    Instruction Manual CyberComm DO 1500 4.1.1 File Options (File) See Figure 10. Select File Options from the File drop down menu. Enter the relevant information for useful future references and type a file name/or file location that you wish to store these details. Click OK upon completion to save information.
  • Page 13: Sub Menus & Function Icons On The Cybercomm Program

    Instruction Manual CyberComm DO 1500 Sub menus & Function Icons on the CyberComm Program See Figure 12. The figure shows the CyberComm Pro software Main Menu after linking with the meter. From this menu, most of the meter key functions can be emulated except calibration of DO probe and CAL EDIT key function. This Sub Menu has following features: Figure 12: Running CyberComm Pro/ Complete Main Menu (Connected to meter)
  • Page 14: Function Icons

    Instruction Manual CyberComm DO 1500 4.2.1 Function Icons See Figure 13. See also Figure 12. The function icons on the main menu each serve a vital role in the CyberComm Pro software, providing user friendly one click access. Figure 13: Function Icon Panel (extracted from Figure 12) Icon Function Name Description...
  • Page 15 Instruction Manual CyberComm DO 1500 Figure 14: Record overwrite prompt Figure 15: Print screen...
  • Page 16 Instruction Manual CyberComm DO 1500 Icon 11: Meter Settings See Figure 16. Program your meter functions via this icon on CyberComm Program. a) Temperature I) Temperature Units of Measurement - Select °C or °F as required (Default is °C) b) Pressure I) Pressure - Select from a range of 425 to 850 mmHg (Default is 760 mmHg)
  • Page 17: Measurement Mode

    Instruction Manual CyberComm DO 1500 Continue from Section 4.2 Refer back to Figure 12 on page 9. 4.2.2 Measurement Mode This indicates the current mode of measurement of the meter; you can change the mode by selecting from the drop down menu to choose between the parameters; %Saturation and mg/L. 4.2.3 Show Cursor Use the ‘Show cursor’...
  • Page 18: To Quit Cybercomm Program

    Instruction Manual CyberComm DO 1500 To quit CyberComm Program See Figure 18. Choose Exit from drop down menu of File or Click the ‘X’ button on the top right hand corner of the window. A pop-up menu will prompt you to save settings; select Yes if you want the settings you set to be available for next usage.
  • Page 19: Retrieve Recorded Data

    Instruction Manual CyberComm DO 1500 RETRIEVE RECORDED DATA © © You are able to view the Recorded Data Readings in a Microsoft Excel spreadsheet or on your Notepad © WordPad etc. To record and retrieve data in a measurement 1. Follow the steps in Section 3.2: Data Log Options (File) and enter the required information before a measurement you want to keep record of.
  • Page 20 Instruction Manual CyberComm DO 1500 © Figure 20: Recorded Data in every 10 seconds displayed in Microsoft Notepad...
  • Page 21: Export Data Readings

    Instruction Manual CyberComm DO 1500 EXPORT DATA READINGS © © You are able to view the Data Readings in a Microsoft Word document, Microsoft Excel spreadsheet or on © © your Notepad WordPad etc. Steps to export data readings from CyberComm Professional: In CyberComm Professional:- 1.
  • Page 22: Paste Data In Microsoft Excel

    Instruction Manual CyberComm DO 1500 © Paste data in Microsoft Excel WordPad and Notepad Follow steps instructed in Section 6.1: Steps to export data readings from CyberComm Professional: and paste the data copied from the CyberComm Pro to a new document. ©...
  • Page 23 Instruction Manual CyberComm DO 1500 © Figure 23: Paste data readings in a Microsoft Notepad document...
  • Page 24: Print Readings

    Instruction Manual CyberComm DO 1500 PRINT READINGS Printing using a serial printer Connect the CyberScan DO 1500 bench meter to the serial printer via RS232C cable (refer to the list of accessories). The configuration of the RS232C port is as shown below. Pin Number Description Transmit Data...
  • Page 25 NOTES:...
  • Page 26 NOTES:...
  • Page 28 For more information on Eutech Instruments’ products, contact your nearest distributor or visit our website listed below: Eutech Instruments Pte Ltd. Distributed by: Blk 55, Ayer Rajah Crescent, #04-16/24 Singapore 139949 Tel: (65) 6778 6876 Fax: (65) 6773 0836 E-mail: marketing@eutechinst.com...

This manual is also suitable for:

Cybercomm pro 2.4

Table of Contents