Data File Tab: Sql Server Database Component Properties - HP X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server User Manual

Automated storage manager
Hide thumbs Also See for X1600 - StorageWorks Network Storage System 5.4TB SAS Model NAS Server:
Table of Contents

Advertisement

Property
Application Server Volume - Name
Application Server Volume - Status
Application Server Volume - Exclus-
ive Storage
Application Server Volume - RAID
Level
Application Server Volume - RAID
Stripe Size
Application Server Volume - Read
Cache
Application Server Volume - Write
Cache
Application Server Volume -
Number of Hot Spares
Application Server Volume - Mount
Paths
Warning Threshold tab—(SQL Server database component) Allows you to change the percent full
warning threshold value for the database component. See
threshold
on page 26 for more information.
Data File or Log tab— (SQL Server database component) One of these two tabs is available de-
pending on whether the database component is a data file or log.
Data File tab—Displays the data file's free space and the following storage allocation details about
the SQL Server data file:
Table 18 Data File tab: SQL Server database component properties
Value
Data File Name
Filename
File Group
Data File Space Available
Value
Name of the volume on the server that hosts SQL Server to which SQL
Server saves the database component's data. The volume resides on the
iSCSI LUN (logical disk) exported by ASM to the server that hosts SQL
Server.
Status of the volume on the server that hosts SQL Server where the data-
base component is stored.
Indicates if database component storage is configured with exclusive
storage. See
Table 5
on page 23 for more information.
The RAID level to which the database component storage is configured.
See
Customizing RAID levels
The RAID stripe size to which the database component's storage is con-
figured. See
Table 5
on page 23 for more information.
Speeds up reads when enabled. This setting is determined by the storage
array, not ASM.
Speeds up writes when enabled. This setting is determined by the storage
array, not ASM.
The number of hot spares with which the database component storage is
configured. See
Table 5
on page 23 for more information.
Path the volume is mounted on, on the server that hosts SQL Server. The
volume is built on the iSCSI LUN exported by ASM to the server that hosts
SQL Server.
Description
Name of database data file.
Relative path to where the database data file is stored on the server
that hosts SQL Server.
File group of data file. This value is assigned by SQL Server.
Free storage space available for data file.
HP StorageWorks X1000 Automated Storage Manager
on page 25 for more information.
Setting a percent full warning
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks x1000

Table of Contents