A-2 Troubleshooting

Diagnostic Test

The diagnostic test will test the CD-ROM server's memory and
the operation of the connected drives.
Before using the diagnostic test:
Users who are currently accessing the CD-ROM server will
be interrupted.
The diagnostic test is only available for the first hour after
you power on or restart the CD-ROM server. Also, you must
restart the CD-ROM server before you can repeat the
diagnostic test.
To test the data transfer operation of a CD-ROM drive, the
drive must have a CD-ROM inserted with a file larger than
10 Mbytes on it.
Conduct the diagnostic test as follows:
1. If using a Web browser, start the browser and enter the URL
of the server's diagnostic page:
http://<IP address>/config/html/diag.htm
2. Make sure that a suitable CD-ROM is inserted into each of the
drives whose operation is to be tested. To test the data transfer
operation of a CD-ROM drive, the drive must have a CD-ROM
inserted with a file larger than 10 Mbytes on it.
3. To start the diagnostic test, simply reload the diagnostic page
in the Web browser. The test may take several minutes. When
it is complete, you must again reload the diagnostic page to
display the results.
Any further reloading of the diagnostic page will simply
show the same test results. You must restart (power cycle)
the CD-ROM Server before you can repeat the diagnostic
test.