REQUEST PARAMETER VALUE (17h)
NOTE: This procedure is only implemented in the GSP-2101 Version 3.xx software.
SYS_HEAD, 17
mm
The effect module's position in the Algorithm
pp
The Paramter's position in the effect module.
When a Request Parameter Value procedure is received, the device will respond with a
Receive Parameter Value procedure.
RECEIVE PARAMETER VALUE (18h)
NOTE: This procedure is only implemented in the GSP-2101 Version 3.xx software.
SYS_HEAD, 18
mm
The effect module's position in the Algorithm
pp
The Paramter's position in the effect module.
vv
The Parameter's value
When a Receive Parameter Value procedure is received, the device's valid Parameter
value is updated with vv.
RECEIVE KEY SCAN CODE (54h)
SYS_HEAD, 54
cc
Code for the Key Scan
The Receive Key Scan Code procedure is used to emulate a button press on the front
panel of a DigiTech Device. See the Key Scan Code Maps (page 18) for a list of Key
Scan codes.