Array Configuration Utility Command Line Interface (Acu-Cli) Overview; Msa Command Line Interface (Msa-Cli) Overview; Array Diagnostics Utility (Adu) Overview; Hp Systems Insight Manager (Hp-Sim) Overview - HP 201723-B21 - StorageWorks Modular SAN Array 1000 Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive:
Table of Contents

Advertisement

ACU website:
softwaer-management/acumatrix/index.html.
Array Configuration Utility Command Line Interface (ACU-CLI)
overview
The Array Configuration Utility Command Line Interface (ACU-CLI) is a command line user interface used
to configure an array controller and its storage.
The ACU-CLI is supported for use in Windows, Linux, and HP-UX environments and can run locally
through a browser, remotely through HP Systems Insight Manager (HP-SIM), or offline from the MSA
Support Software CD.
For more information about the ACU-CLI, see the following:
ACU-CLI section of the array configuration reference guide, available on the Documentation CD or the
Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000.
ACU-CLI text file, available in the ACU-CLI folder on the Support Software CD.

MSA Command Line Interface (MSA-CLI) overview

The MSA Command Line Interface (MSA-CLI) is built into the MSA array controller firmware and offers a
command level method of configuring, managing, and monitoring the array controller and its storage.
The MSA-CLI is accessed through a host computer connected to the customized RJ-45Z serial port on the
front of the MSA controller.
This interface is provided for system administrators who prefer this method of system management,
instead of a graphical user interface. All supported operating systems can access the CLI.
Sample tasks include: configuring the storage units (LUNs), limiting access to the storage, and viewing
controller and storage setup and status information.

Array Diagnostics Utility (ADU) overview

The HP Array Diagnostic Utility (ADU) is a web-based application that creates a report on all HP
storage controllers and hard drives. This report provides vital information to assist in identifying faults or
conditions that may require attention.
Collected information includes:
Hard drive errors
Intermittent problems
Pre-failure Notification
Controller, array, and logical drive problems
Third-party, possible counterfeit, or non-HP hard drives
Array controller and hard drive firmware versions
Length of hard drive service
Physical and logical drive configuration information
Serial numbers of hard drives and array controllers
The ADU is installed on a server in the network and is provided on the MSA Support Software CD.

HP Systems Insight Manager (HP-SIM) overview

HP Systems Insight Manager (HP-SIM) is a web-based application that allows system administrators
to accomplish normal administrative tasks from any remote location, using a web browser. HP-SIM
provides device management capabilities that consolidate and integrate management data from HP and
third-party devices. HP-SIM reports hardware fault conditions (both failure and pre-failure) and collects
30
Available diagnostic tools
http://h18000.www1.hp.com/products/servers/priliantstorage/

Advertisement

Table of Contents
loading

This manual is also suitable for:

353803-b22 - storageworks modular smart array 1000 san starterStorageworks 1000 - modular smart arrayStorageworks 1000

Table of Contents