Download Print this page
Delta Electronics Network Device DVPAEXT01-H Instruction Sheet
Delta Electronics Network Device DVPAEXT01-H Instruction Sheet

Delta Electronics Network Device DVPAEXT01-H Instruction Sheet

Delta electronics network device instruction manual

Advertisement

Quick Links

Warning
Read this instruction sheet carefully before using DVPAEXT01-H.
DVPAEXT01-H is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust,
humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the
device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may
occur.
DVPAEXT01-H (including DVPAEXT1L-H and DVPAEXT1R-H) is used for connecting MPU and extension unit or
among extension units. Use DVPACAB4A09/DVPACAB4A18 to extend the transmission distance between
DVPAEXT1L-H and DVPAEXT1R-H.
Make sure the power of the MPU and extension unit is switched off when wiring and power on MPU and the
extension unit after the installation of DVPAEXT01-H is completed.
Introduction
Thank you for choosing Delta's DVP series accessory. DVPAEXT01-H is a connector for the extension cable
of extension units. The maximum extension distance available is 1.8m. DVPAEXT01-H is only applicable for
the connection between DVP-EH/EH2/PM series MPU and DI/DO, AI/AO extension units and does not
occupy any extension point or module space.
Product Profile & Outline
DVPAEXT1L-H in the left side (prior level)
6
3
5
3
4
1
Upper cover of connection port
2
Terminal for extension cable
3
DIN rail clip
DVPAEXT1R-H in the right side (next level)
5
1
6
1
2
6
6
4
Unit: mm
4
DIN rail
5
Extension cable
6
Direct fixing hole

Specifications

Item
Power supply
Power consumption
Noise immunity
Operation/storage
Shock/vibration
immunity
Weigh (g)

Installation and Wiring

Connect DVPAEXT01-H with modules
Using DVPAEXT01-H to connect DVP-EH/EH2/PM series MPU with DI/DI, AI/AO extension units.
Cable Connection
When installing DVPAEXT1L-H and DVPAEXT1R-H, please use DVPACAB4A09/DVPACAB4A18
connection cable.
Note: The DVPAEXT01-H package does not contain the connection cables mentioned above. Please purchase the
cables from our distributors.
注 意 事 項
ENGLISH
DVPAEXT01-H
產 品 簡 介
DVP-EH/EH2/PM
產 品 外 觀 及 各 部 介 紹
DVPAEXT1L-H
3
5
3
3
1
2
3
DIN
Model
DVPAEXT01-H
DVPAEXT1L-H
Supplied by MPU through its internal bus: 5V DC (4.5 VDC ~ 5.5 VDC) (-10% ~ 10%)
0.5W
ESD: 8KV Air Discharge
EFT: Power Line: 2KV
RS: 26MHz ~ 1GHz, 10V/m
Operation: 0° C ~ 55° C (temperature), 50 ~ 95% (humidity), pollution degree 2
Storage: -25° C ~ 70° C (temperature), 5 ~ 95% (humidity)
International standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)
100
TO DVPAEXT1L-H
25
13
14
1
25 PIN D-SUB
DVPAEXT1L-H COM Port
DVPAEXT1R-H COM Port
25 PIN D-SUB female
25 PIN D-SUB f emale
1
1
. .
25
25
OPEN TYPE
DVPAEXT1L-H
DVPAEXT1R-H
DVPAEXT1L-H
DVPAEXT1R-H
DVP
DI/DO AI/AO
6
5
1
3
2
6
3
4
mm
4
DIN
5
6
DVPAEXT1R-H
0.5W
100
TO DVPAEXT1R-H
1
14
25
13
25 PIN D-SUB
繁 體 中 文
DVPACAB4A09/DVPACAB4A18
1.8
DVPAEXT1R-H
1
6
3
6
3
4
3

Advertisement

loading

Summary of Contents for Delta Electronics Network Device DVPAEXT01-H

  • Page 1: Specifications

    Warning Read this instruction sheet carefully before using DVPAEXT01-H. DVPAEXT01-H is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g.
  • Page 2 功 能 規 格 DVPAEXT01-H DVPAEXT1L-H 5 VDC 4.5 ~ 5.5V DC 0.5W ESD 8KV Air Discharge EFT Power Line: 2KV 26MHz~1GHz, 10V/m 0°C ~ 55°C 50 ~ 95% / -25°C ~ 70°C 5 ~ 95% / IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea) 安...