7.22 System log
Group: syslog
NAME
VALUE
enableremotelog
<boolean>
serverip
<IP address>
serverport
514,
1025~65535
level
0~7
setparamlevel
0~2
7.23 camera PTZ control
Group: camctrl (capability.camctrl.httptunnel > 0)
NAME
VALUE
enablehttptunnel
<boolean>
Group: camctrl_c<0~(n-1)> for n channel product
NAME
panspeed
tiltspeed
zoomspeed
SECURITY
(get/set)
6/6
6/6
6/6
6/6
6/6
SECURITY
(get/set)
4/4
VALUE
SECURITY
(get/set)
-5 ~ 5
1/4
-5 ~ 5
1/4
-5 ~ 5
1/4
DESCRIPTION
Enable remote log.
Log server IP address.
Server port used for log.
Levels used to distinguish the importance of
the information:
0: LOG_EMERG
1: LOG_ALERT
2: LOG_CRIT
3: LOG_ERR
4: LOG_WARNING
5: LOG_NOTICE
6: LOG_INFO
7: LOG_DEBUG
Show log of parameter setting.
0: disable
1: Show log of parameter setting set from
external.
2. Show log of parameter setting set from
external and internal.
DESCRIPTION
Enable HTTP tunnel for camera control.
(capability.ptzenabled)
DESCRIPTION
Pan speed
Tilt speed
Zoom speed
VIVOTEK