TEST AND ADJUSTMENT

❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
fore it will detect motion. When first turned on
or when switching modes wait 1
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), D
and the ON-TIME control to the TEST position.
NORMAL SOFT FLASH
ON-TIME
MIN
MAX
TEST 1 5 20
RANGE
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or unwanted traffic may trigger
the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
/
minute warm up period be-
1
2
/
minutes.
1
2
B
to OFF,
®
ual
rite
LAMP MODE
DUAL BRITE™
OFF 3 6 DUSK TO
MINUTES
HOUR
DAWN
100 ft.
(30.5 m)
Boosted
Maximum
Coverage Angle
The detector is most sensitive to motion across its field
of view.
Motion
Least Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
270°
❒ Set the D
B
ual
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
❒ Set the LAMP MODE switch to the desired light
turn-on effect (Normal, Soft, Flash).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
Sensing Angle . . . . . . Up to 270°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
Lamp Modes . . . . . . . Normal, Soft, Flash
Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . T4, 100W maximum G8 halogen
D
B
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
®
ual
rite
4
Motion
Sensor
Most Sensitive
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
switch to the amount of time after
®
rite
(30.5 m) with Range Boost.
[var ies with surrounding
temperature]
candescent [Up to 100 Watt
Maximum each lamp holder].
MODE
bi-pin 120 VAC
Clamp
Screw
Ball
Joint
598-1309-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dualbrite 57985798

Table of Contents