After the test is complete, the results are displayed as illustrated below.
Use this table to define the result codes.
Code
Test
A-trigs
7
connectivity
11
Stylus excitation
Sensor Antenna
14
disconnects
Sensor Antenna
15
shorts
Channel
18
imbalance
Capacitor
19
calibration
Internal Firmware
47
Error
Critical
48
Malfunction
Page 17 of 94
Dell
Latitude™ XT2 XFR Service Manual
Digitizer Self Test Result Codes
Error Details
Digitizer analog
Digitizer is unable to initialize or read samples from analog
processor fail
processor. No pen or touch position is reported.
Signals received during the stylus excitation test are below
No pen excitation
certain limit. Pen may be not functional or detected in tip
only.
Digitizer grid
There are disconnected lines. Pen or touch may be
disconnect
malfunctioning in a specific physical display area.
Digitizer grid
There are shorted lines. Pen or touch may be malfunctioning
shortcut
in a specific physical display area.
Digitizer channel
There is an unbalanced channel. Pen or touch may be
degraded
malfunctioning in a specific physical display area.
Digitizer
The calibration capacitor in a certain channel is set to
calibration
minimal or maximum value. Pen or touch may be
degraded
malfunctioning in a specific physical display area.
Internal
Firmware resource problem in executing diagnostics.
Firmware Error
Diagnostics tool is not functional.
Device Error
Critical malfunction was detected, test cannot continue.
Symptoms
Version A00-01