Process After Fixing Flash Error - Sony Handycam HDR-HC5 Service Manual

Digital hd video camera recorder
Hide thumbs Also See for Handycam HDR-HC5:
Table of Contents

Advertisement

Self-diagnosis Code
Block
Detailed
Function
Code
E
6
1
1
0
E
6
1
1
1
E
6
2
0
0
E
6
2
0
1
E
6
2
0
2
E
6
2
0
3
E
6
2
1
0
E
6
2
1
1
E
6
2
1
2
E
6
2
2
0
E
9
1
0
1
Note: After repair, be sure to perform "1-6. PROCESS AFTER FIXING FLASH ERROR".

1-6. PROCESS AFTER FIXING FLASH ERROR

When "FLASH error" (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the
following process.
Order Page Address Data
1
7
01
2
7
00
3
7
02
HDR-HC5/HC5E/HC7/HC7E_L2
Symptom/State
Zoom operations fault.
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch).
Shift lens overheating (Yaw).
Abnormality of thermistor.
Abnormality when flash is being charged.
Procedure
75
01
Press PAUSE (Write) button.
Check the data changes to "01".
Inspect the zoom MR sensor of lens block (Pin qh, qk of CN5302
(HC5/HC5E) or Pin w;, wa of CN5301 (HC7/HC7E) on the LD-
221 board) when zooming is performed when the zoom switch is
operated and the zoom motor drive circuit (IC5404 on the LD-221
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE8202 on the CM-076 board
(HC5/HC5E) or SE7202 on the CM-077 board (HC7/HC7E))
peripheral circuits.
Inspect yaw angular velocity sensor (SE8201 on the CM-076 board
(HC5/HC5E) or SE7201 on the CM-077 board (HC7/HC7E))
peripheral circuits.
Refer to [1-7-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred] (HC7/HC7E only).
Inspect the steadyshot circuit (IC5703 on the LD-221 board)
(HC7/HC7E only).
Refer to [1-7-2. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred] (HC7/HC7E only).
Refer to [1-7-3. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred] (HC7/HC7E only).
Refer to [1-7-4. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred] (HC7/HC7E only).
Refer to [1-7-5. E : 62 : 20 (Abnormality of Thermistor)
Occurred] (HC7/HC7E only).
Checking of flash unit or replacement of flash unit. (Note)
1-4
ENGLISH
ENGLISH
Correction
JAPANESE
JAPANESE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Handycam hdr-hc7Handycam hdr-hc5eHandycam hdr-hc7e

Table of Contents