TC/UB Menu

* Default values are indicated in bold characters.
Item
Setting Values
TC Generator
Free Run
Rec Run
Regen
TC Preset
UB Preset
Drop Frame
Non Drop
Drop
For setting the operation of the time code.
Free Run
: The time code operates in the run mode at all times regardless of the recording
status. It continues to run even when the power of the camera recorder is turned
off.
Rec Run
: The time code operates in the run mode during recording. It continues to run in the
order of the recorded clips as long as the SDHC/SDXC card is not replaced. If the
SDHC/SDXC card is removed and recording is made on another card, time code
will be recorded on the new card from where it was left off in the previous card.
Regen
: The time code operates in the run mode during recording. When the SDHC/SDXC
card is replaced, the last time code recorded on the card is read and recorded on a
new card so that the time code continues in running order. (A Page 39)
^
For setting the time code (hour, minute, second, frame).
Display
: Drop setting
: Non Drop setting 02:02:25:20
Memo :
● When [TC Generator] is set to Regen , this item appears as <Regen> and cannot be
selected.
^
For setting the user's bit. (Digit by digit)
Display : AB CD EF 01
Memo :
● When [TC Generator] is set to Regen , this item appears as <Regen> and cannot be
selected.
For setting the framing mode of the time code generator.
Non Drop : Internal time code generator works in the non-drop-frame mode. Use this setting
when placing emphasis on the number of frames.
Drop
: Internal time code generator works in the drop-frame mode. Use this setting when
placing emphasis on the recording time.
Memo :
● This item can be set only when the frame rate of [Frame & Bit Rate] in the [Record
Set]B[Record Format] menu is set to 60p , 30p , or 60i . When the frame rate is 24p ,
Non Drop becomes fixed and cannot be selected. When the frame rate is 50p , 25p , or
50i , this item appears as --- and cannot be selected. (A Page 63)
Function
02:02:25.20