reads being reported you should enable only the tracks you
expect data to read for data. In addition, the reader can
read data when the card is inserted, removed or in both di-
rections. Finally, the card reader can be globally enabled or
disabled. Parameters to be set should be set in a single
command, with options separated by semicolons:
Command: {CMR:data} Configure Magnetic Card Reader
– requires data.
CMR data:
"
"
"
"
"
"
"
EXAMPLE:
Turn T1&2 ON, T3 OFF, and the auto print ON:
"
"

Smart Card Operational Commands

Since Smart Card applications and card types can vary
widely, the printer acts only as a conduit to the card, relay-
ing commands to the card and accepting data back from the
card.
Most cards require special commands of their own. The
commands shown here are commands to the reader, not to
the card.
4-42
Intermec Portable Printers Technical Reference Manual
T1:ON or OFF to enable or disable reading Track I
T2:ON or OFF to enable or disable reading Track II
T3:ON or OFF to enable or disable reading Track III
E:ON or OFF to enable or disable the magnetic card
read
D:IN or OUT or BOTH for card read direction
S:ON or OFF to enable or disable auto RS--232 send of
data on reading
A:ON or OFF to enable the auto print stand--alone
demo
1 – put the printer into Easy Print by sending 3 char-
acters ESC+EZ
2 – configure by sending
{CMR:T1:ON;T2:ON;T3:OFF;A:ON}