Back Of The Switch; Power Connector; Slot For Redundant Power Supply - HP J4865A Installation And Getting Started Manual

Procurve series 4100gl switches
Hide thumbs Also See for J4865A:
Table of Contents

Advertisement

Back of the Switch

.

Power Connector

The Series 4100gl Switches do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.

Slot for Redundant Power Supply

A second, load-sharing redundant power supply (HP ProCurve Switch gl/xl
RPS, HP J4839A) can be installed in the back of the Series 4100gl switches. To
provide true redundancy, this second power supply should be connected to a
different AC power source from the other supply. Then, if one AC power
source fails, the switch will continue to run.
C a u t i o n
The switch power supplies are hot swappable, but, as indicated by the caution
statement on the power supply, it must be disconnected from AC power
before being installed or removed.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
AC power connector
Introducing the HP ProCurve Series 4100gl Switches
slot for installing optional
redundant power supply
Back of the Switch
1-9