The default setting for all TCP/IP variables is 0.0.0.0.
Out-of-Band Management and Console
Settings
You can use the Out-of-Band/Console Setting menu to choose
whether to use the hub's RS-232 serial port for console manage-
ment or for out-of-band TCP/IP communication using SLIP, and
to set the baud rate used for SLIP communications.
The following fields can be set:
? System Restart Out-of-Band Baud Rate.
rameter determines the serial port baud rate that will be
used the next time the hub is restarted. It applies only
when the serial port is being used for out-of-band (SLIP)
management; it does not apply when the port is used as a
console port. Available speeds are 1200, 2400, 9600, and
19200 bits per second.
Master Hub Setup and Management