9. MAINTENANCE
9.2
A
M
NNUAL
AINTENANCE
Your unit is equipped with a wall controller (ACCGSC1 or 40425), which tells when to perform maintenance when the Filter Maintenance
light stays ON. Otherwise, this maintenance must be performed once a year to ensure your unit proper operation for years to come.
Proceed as the Semi-annual Maintenance (Section 9.1), but instead of replacing the prefilter (point 4), discard the complete HEPA Filter
cartridge (including prefilter). Install a new HEPA filter cartridge with a new prefilter on it.
NOTE: In annual maintenance, for 40425 wall controller, press simultaneoustly both
and turn the LED off.
9.3
O
A
PTIONAL
LPINE
During pollen season, or as needed, remove the assembled hood from its backplate by removing its
2 retaining screws.
Then, slide out the optional Alpine/pine filter and clean it under water. Let dry before reinstalling it on the
assembled hood. Reinstall the hood on its backplate.

10.TROUBLESHOOTING

PROBLEMS
1.Unit does not start at Low
or High position.
2.Unit does not run at Low
speed, but runs at High.
3.Unit is not operating as per
the selected mode.
4.Wall control indicators do not work
properly or not at all.
5.On 40425 wall controller only, 1 or 2
light indicators are flashing every second.
6.On 40425 wall controller only,
wall controller screen indicates E1.
7.On 40425 wall controller only,
wall controller screen indicates E2.
If the problem is still not solved, call your installer or the nearest approved Service Center.
Also, you can reach the Customer Service Departments or Technical Supports listed below.
(CONT'D)
(
)
ESSENTIAL
/
F
(
PINE
ILTER
PART NUMBER
SOLUTIONS
• Check breaker or fuse in main distribution panel or GFI outlet.
• Check there is 120V at the electrical outlet.
• Make sure the unit main switch is properly set in Normal or Boost position.
• If a wall control (ACCGSC1 or 40425) is connected, disconnect control wire from the
unit, then make sure the unit main switch is properly set in Normal/Remote or Boost
position.
• Check the fuse on electronic board. If blown, replace with the same type.
• If a wall control (ACCGSC1 or 40425) is used, disconnect control wire from the unit.
Then, if the unit runs at Normal speed, check control wiring and wall control connections.
• Check if the unit main switch is in "Normal/Remote" position.
• Check wall control wiring.
• Check wall control wiring.
• Check if the unit main switch is in "Normal/Remote" position.
• Check wall control wiring.
• Check wall controller wiring.
• The temperature sensor is defective. (The unit will automatically switch to OFF mode
if this happens.)
• Customer Service Department:
Telephone:
Fax:
• Technical Support:
Telephone:
Fax:
: ACCGSUP5)
Broan-NuTone LLC
1-800-558-1711
1-800-356-5862
1-800-637-1453
1-262-673-8709
- 35 -
and
buttons for 5 seconds to reset the counter
VD0124