Installing Two Exterior Hoods - NuTone GSEH3K Installation Instructions Manual

Broan-nutone gseh3k air purifiers: install guide
Hide thumbs Also See for GSEH3K:
Table of Contents

Advertisement

Available languages

Available languages

6. INSTALL THE UNIT
6.7 I
A
D
NSTALLING
IR
6.7.4 O
A
PTIONAL
LPINE
The special design of this filter makes it much more efficient to catch spores and their particles during
intensive pollen season. Using this optional fine mesh filter will extend the life expectancy of your prefilter.
To install it, remove the bottom metal screen of the AirDuo™ exterior hood and replace it by the optional
Alpine/pine filter. See illustration beside.
(Alpine/pine filter part number: ACCGSUP5)
During pollen season, or as needed, remove the asembled hood from its backplate by removing its 2 retaining screws. Then, slide out
the Alpine/pine filter and clean it under water. Let dry before reinstalling it on the assembled hood. Reinstall the hood on its backplate.
6.8 I
T
NSTALLING
WO
6.8.1 A
SSEMBLING
Both exterior AirDuo™ hood and optional exterior
single hood require assembly. Assemble the top
metal screen, the plastic grille and the bottom metal
screen to the AirDuo™ exterior hood*. Use provided
screws. Slide the bottom metal screen into the single
exterior hood base. See illustrations beside.
*Patent pending
6.8.2 L
OCATING THE
Due to its particular design, the AirDuo™ exterior hood must be used only for exhaust hood when performing an installation
using 2 exterior hoods. Use the optional single fresh air intake exterior hood for supply air.
Make sure the optional exterior single hood is at least 6 feet (1.8 m) away (or more, as per applicable building codes or standards)
from sources of contamination such as:
• High efficiency furnace vent.
• Gas meter exhaust, gas barbecue-grill.
The AirDuo™ exterior hood must be installed at a minimum distance of 4 inches (102 mm) from the ground, and the optional single fresh
air intake exterior hood must be installed at a minimum distance of 18 inches (457 mm) from the ground. Also, a minimum distance of
6 feet (1.8 m) is required between the hoods to avoid cross-contamination. See illustration below.
AirDuo™
Exhaust hood
VD0094
(CONT'D)
™ E
H
UO
XTERIOR
OOD
/
F
PINE
ILTER
E
H
* (GSVH1K, GSHH3K
XTERIOR
OODS
E
H
XTERIOR
OODS
A
D
O
IR
UO
AND
PTIONAL
6'
(1.8 m)
4''
(102 mm)
* (GSVH1K, GSHH3K
AND
VO0024
AirDuo™
EXTERIOR HOOD
E
S
H
XTERIOR
INGLE
OOD
CAUTION
WARNING
!
0
• Any exhaust from a combustion source.
• Garbage bin.
Intake hood
18''
(457 mm)
Optional location
- 21 -
GSEH3K
AND
MODELS ONLY
VA0024
GSEH3K
MODELS ONLY
VO0030
OPTIONAL SINGLE FRESH AIR INLET
EXTERIOR HOOD
6'
(1.8 m)
4''
(102 mm)
)
(
'
)
CONT
D
)