Haier HPU-18CU13 Operation Manual
Haier HPU-18CU13 Operation Manual

Haier HPU-18CU13 Operation Manual

Split type room air conditioner

Advertisement

Quick Links

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HPU-18CU13
HPU-20CU13
Please read this operation manual before using the air conditioner
No.0010562446

Advertisement

Table of Contents
loading

Summary of Contents for Haier HPU-18CU13

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HPU-18CU13 HPU-20CU13 Please read this operation manual before using the air conditioner No.0010562446...
  • Page 2 Before starting the air conditioner, read the Before disposing an old air conditioner that information given in the User's Guide caref- goes out of use, please make sure it's inop- ully. The User's Guide contains very impor- erative and safe. Unplug the air conditioner tant observations relating to the assembly, in order to avoid the risk of child entrapment.
  • Page 3: Specifications

    3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V...
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    Parts and Functions Indoor unit HEALTH HUMIDITY TIMER TEMP. SLEEP ON/OFF TEMP + TEMP - Outlet Control panel Inlet grille Air filter(inside) UV light degerming device (inside) Inlet Anion generator (inside)
  • Page 7: Display Board

    TIMER 2. Room temperature display, TEMP. SLEEP Setting temperature display 3. HEALTH display 4. TIMER ON / OFF display 5. SLEEP display 6. POWER / SOFT display 7. ON/OFF button Used for unit start and stop. 8. MODE button ON/OFF...
  • Page 8 Press it once again, lock will be AUTO COOL canceled and lock condition display disappears. 7. HOUR button Used to set clock and timer setting. NOTE: 1.Cooling only unit do not have functions and displays related with heating.
  • Page 9: Clock Set

    If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
  • Page 10: Operation

    The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
  • Page 11: Auto Operation

    AUTO COOL Then Select Auto operation 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 12: Cool Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 13: Dry Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: COOL operation starts when room Ultra-low air flow temp.is higher than temp.setting.
  • Page 14: Fan Operation

    Remote controller: AUTO COOL Then Select FAN operation 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: 4.Unit stop Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit will not operate in COOL mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
  • Page 15: Air Flow Direction Adjustment

    NOTE: When we stop the air conditioner with remote controller or controlling plate, the flap will close automatically. If we cut off the power directly, the flap could not close itself. So you should shut off the machine with remote controller or controlling plate, You MUST NOT cut off the power when the machine is running.
  • Page 16: Sleep Operation

    1 hours, temp. rises by 1 C further. Unit stop Temp.setting The unit will run for further 6 hours then stops. In COOL, DRY mode Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
  • Page 17: Timer On/Off Operation

    After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
  • Page 18 " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min. 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"...
  • Page 19: Fan Speed Display

    "Hi". Unit stop (cancel the Test operation:) press the ON/OFF button once, then you will hear "Pi" sound and the unit will operate as what the remote controller shows. When you connect the power supply, all the signs of function will be displayed for 5 senconds.
  • Page 20: Operation Hints

    When sudden power failure happens during unit operation in power failure resume mode,if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 21: Maintenance

    During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. HEALTH TEMP.
  • Page 22 Air Filter cleaning Press the clasp on the top of the grill and pull the grill out, and then the filter will be taken out along a gradient way. Clean the filter.
  • Page 23 To Keep Your Air conditioner in Good Condition after Season. 1. Operate in FAN mode for about half a day. On a fine day, unit shall be started and operate in FAN mode for about half a day until the inside of the unit becomes thoroughly dry.
  • Page 24 Before Setting in High season 1. Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. 2. Connecting the earthing cable.
  • Page 25: Troubleshooting

    This noise is generated by the inspection casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.

This manual is also suitable for:

Hpu-20cu13

Table of Contents