About the I/O cable

The following shows the leads that comprise the I/O cable.
(1)
Power Supply
This connects the power supply.
Use a DC power supply with safe extra-low-voltage circuits to prevent high voltage.
Wire the power supply separately from other devices. Wiring them together or placing them in the same duct may cause induction, resulting
in malfunction or damage.
(2)
GND
The GND terminal is the 0 V power supply terminal.
(3)
OUTPUT (control output)
This outputs judgment results. This lead is interlocked with OUTPUT LED.
(4)
ENABLE (enable output)
This turns ON when the sensor is ready for measurement.
(5)
ERROR (error output)
This turns ON when an error is generated. This lead is interlocked with ERR LED.
(6)
TEACH (teching input)
There are two teaching modes, workpiece stop teaching and workpiece move teaching. These teaching modes can be selected in the menu.
(7)
TRIG (measurement trigger input)
There are two measurement modes, synchronus measurement and continuos measurement. Which mode of measurement is to be per-
formed in is selected in the menu.
(8)
BANK1 (bank swichting input 1)
(9)
BANK2 (bank swichting input 2)
(10) BANK3 (bank swichting input 3)
The bank No. can be switched when the BANK1 to BANK3 are connected as follows
Bank No.
BANK1
OFF
BANK2
ON
BANK3
OFF
BANK4
ON
BANK5
OFF
BANK6
ON
BANK7
OFF
BANK8
ON
ZFV
* : Enabled only in the RUN mode
BANK1
BANK2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Brown
(1) Power supply
Blue
(2) GND
Black
(3) OUTPUT*
Orange
(4) ENABLE
Light blue
(5) ERROR
Yellow
(6) TEACH*
Pink
(7) TRIG*
Gray
(8) BANK1*
Green
(9) BANK2*
Red
(10) BANK3*
Purple
Unused
White
Unused
BANK3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
.
C-9