INTRODUCTION
Turning off the Power
Do not turn the power supply off while the message indicating that processing is being performed
is being displayed. Data in the memory will be destroyed, and the Controller may not operate
correctly the next time it is started.
Using the RESET Signal
Do not input the RESET signal immediately after power supply is turned on. When using the
RESET input to synchronize startup timing, wait at least 1 second after the Controller's power
supply is turned on before turning on the RESET terminal.
Securing the Video Monitor (When Using the Recommended F150-M09)
If the video monitor case is metallic, observe the following precautions to prevent noise
interference, because the video monitor case is connected to the 0V line in the internal circuits.
• Do not ground the video monitor.
• Do not ground the metallic part of the connector.
• Secure the video monitor with plastic screws if it is being mounted to a metallic surface.
Warming Up
After turning on the power supply, allow the Controller to stand for at least 30 minutes before
use. The circuits are unstable immediately after the power supply is turned on and attempting
measurement may result in inconsistent measurement values.
Z550
12
Setup Manual
Example: Saving
Save
Scn 0
Saving