Section 2 NS Series Functions
NS Series Programming Manual
23: Before writing numeral and string
25: When changing numeral or string
26: When selecting a list
30: When Pressing a Display Area
31: When selecting an Alarm/Event
• Error number (1: Program error; 2: 0 allocation error; 3: BCD error; 4: argument error)
This data can be saved as a CSV file to a Memory Card by turning ON system memory bit $SB43.
Example: How to read error logs saved as CSV files.
Example:
2000/02/24 14:18:38,
Macro executed when the touch switch for functional object with ID 2 turned ON in
Meaning:
screen 0 on 2000/02/24 at 14:18:38 PM.
The error occurred because of a macro zero division.
Maximum Number of Records
Up to 100 records can be kept. The set ring buffer format is fixed for records. With the ring buffer format,
the oldest data is deleted when the maximum number of records is exceeded and new data is then
recorded.
Checking Records
Displays the error log from the System Menu during operation.
1. Select Special screen/Error log (Sort by Occurrence) or Error log (Sort by Frequency) from the Sys-
tem Menu.
2. Check the error log.
0, 2, 20, 2
Error number
Macro execution type
Functional object ID
Screen number
Date and time of error