Omron MS4800E Operation Manual page 30

Safety light curtain type 4
Hide thumbs Also See for MS4800E:
Table of Contents

Advertisement

Fixed Blanking
12
4. The user must then press
and release the Start but-
ton or perform a power cy-
cle. The MS4800 receiver
then resets. If no faults are
detected and the state of
the optical beams match-
es the recorded Fixed
Blanking pattern, the re-
ceiver will enter the IN-
TERLOCK or MACHINE RUN condition depending upon the selected Start
Mode. The amber receiver Blanking Active LED will be on.
5. If the 10 minutes period
expires, the amber LED
and IBIs (Individual Beam
Indicators) quit flashing
and the yellow LED (IN-
TERLOCK) goes on. The
user can start another
programming
by
setting
Blanking switches off and
then on. The user may
start normal operation by a press and release of the start button or by per-
forming a power cycle.
6. To exit Fixed Blanking the
user sets both selector
switches to the off posi-
tion, then either presses
and releases the Start but-
ton or performs a power
cycle. The receiver will
power up with the amber
LED off.
Note Please refer for further information to the FAQ to section 17-6.
1
2
1
2
1
2
1
2
sequence
both
Fixed
1
2
1
2
to indicate program switch is disabled.
The yellow LED turns on to indicate the
Start button is active.
Section 5-1
IBIs of blocked
beams off.
on
SWA
3
4
5
6
ON
SWB
3
4
5
6
ON
on
Amber LED is on to indicate
in Fixed Blanking mode.
IBIs of blocked
beams on.
on
SWA
3
4
5
6
ON
SWB
3
4
5
6
ON
on
Amber LED is off to indicate
in Fixed Blanking is disabled.
IBIs of blocked
beams on.
off
SWA
3
4
5
6
ON
SWB
3
4
5
6
ON
off
The amber LED and IBIs quit flashing

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents