Page 1
Most suitable for safety circuits in press machinery, machine tools, and other production machinery. CE mark (EC Low-voltage Directive 73/23/EEC) Track-mounting and Back-mounting Sockets are available. Note: Be sure to refer to the Precautions on page 7. Ordering Information Model Number Legend G7S-jAjB NO Contact Poles...
110% (V) Approx. 0.8 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of 15%. 2. Performance characteristics are based on a coil temperature of 23 C 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum.
Life Expectancy (240 VAC; cos =0.4, cos =1) Life Expectancy (AC15, DC13 IEC947-5-1/Table 4) 6,050 operations min. (AC15, 240 VAC, 3 A, cos 0.3) 6,050 operations min. (DC13, 24 VDC, 1 A, L/R 100 ms) VDE approved. I (Current) Switching current (A)
Page 4
Dimensions Note: All units are in millimeters unless otherwise indicated. Safety Relays G7S-4A2B G7S-3A3B Terminal Installation/Internal Connection Diagram (Bottom View) G7S-4A2B 62 max. 22.5 max. Cross-section of 24 VDC Mounting Holes 37 max. G7S-3A3B 5 min. Fourteen, 1.8 dia. 24 VDC...
Page 5
39 max. P7S-14P Back-mounting Socket (PCB Terminals) 61.5 max. Terminal Installation/Internal Connection Diagram 23 max. (Bottom View) G7S-4A2B Two, 6.5 dia x 7.9 deep Cross-section of Mounting Holes 29 max. G7S-3A3B 23 max. With Safety Relay Mounted Two, 3.6 dia.
Page 7
Forcibly Guided Contacts When NO contacts are welded, the coil will be non-energized so all NC contacts will maintain a distance between the contacts of 0.5 mm mini- mum. Likewise if NC contacts are welded, the coil will be energized so all contacts will maintain a distance between each other of 0.5 mm minimum.
Page 8
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J107-E1-2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Control Components Division H.Q.