Increasing Processing Speed for Area
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 57
Measurement Data That Can Be Logged for Area
The following values can be logged as measurement data.
Measured item
Range of value
−360,960 to 360,960
D. Area
7-4 Logging Measurement Data and Image Data: p. 98
Errors
Errors in Teaching
A teaching error message will appear if the reference area registered during teaching is 0. Perform the
following.
• If the color of the measurement object has changed from the specified color, set the color again and try
teaching again.
If the specified color is not found during teaching, the reference area will be registered as 0. If having no area is
OK, adjust the judgement parameters with this value as the reference.
FQ User's Manual
Description
This is the difference between the standard color area and
the measured color area.
Inspecting with the Area Inspection Item
69