If a problem occurs ...
Problem
None of the diversity
displays I or II appears on
the display panel
During the soundcheck,
only one diversity display
(I or II) appears on the
display panel
If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions,
please contact your local Sennheiser partner for assistance.
To find a Sennheiser partner in your country, search at www.sennheiser.com under "Service & Support".
36
Possible cause
Receiver's squelch threshold is adjusted too
high
Transmitter's RF signal is too weak
One of the antennas is not correctly
connected
Antennas are not optimally positioned
Possible solution
Reduce the squelch threshold (see page 17).
Increase the transmission power of the
transmitter.
Reduce the distance between transmitter
and receiving antennas.
Check the antenna cables or the antennas.
Reposition the antennas.