Search Band Programming
In this mode, the search bands (1-0) used to perform searches are programmed with starting and ending
frequencies as well as step sizes and receive modes.
Searching
In this mode, the searching operation checks for active transmissions on the frequencies in the specified
search range. There are two searching modes which can be performed.
The two modes are :
VFO:
starts searching from the current VFO frequency
Band:
search a preprogrammed search band
Search Pass
The radio is in Search Pass mode when a blinking P indicator is visible and the contents of the Search Pass
memory are being displayed.
VFO
The radio is in VFO mode when there is a frequency displayed but no memory channel or 'CH' LCD
indicator present. Pressing the MR key toggles between VFO and Memory modes.

Terminology

When you see 'FUNC + key'
Press FUNC
You will hear a beep (if enabled) and FUNC will be displayed
Press 'key'

Mode Operations

VFO Mode

VFO holds:
Frequency
Step size
Receive mode
Attenuator
Delay
Skip
How to change the frequency
Simply key in the desired frequency
1. Enter the frequency
2. If you make a mistake during entry
A. Press C/AC
B. Use arrow keys to select digit to be corrected
C. Change digit using key press or rotary control
D. Press ENT when completed
3. Press ENT
NOTE: Instead of correcting at step 2 above, simply press C/AC twice and start over with the frequency entry.
Use the rotary control or arrow keys
Use the rotary control or arrow keys to increase or decrease the currently displayed frequency by the
currently set step size. Holding down an arrow key will change the frequency rapidly.