10.2 Burner and Nozzle Data Tables
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Ultra-rapid (4)
Ultra-rapid (5)
Fish (6)
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Ultra-rapid (4)
Ultra-rapid (5)
Fish (6)
To identify the burners on your hob, refer to the drawings in point "4.
GETTING TO KNOW YOUR APPLIANCE".
52
Instructions for the Installer
R
ATED
HEAT
CAPACITY
(
W)
K
Nozzle
diameter
1/100 mm
1.05
50
1.75
65
2.3
75
3.5
94
3.9
100
1.9
65
R
ATED
HEAT
CAPACITY
(
W)
K
Nozzle diameter
1.05
1.75
2.5
3.5
3.9
1.9
LPG GAS – G30/G31 28/37 mbar
Reduced
By-pass
heat
mm
capacity
1/100
(W)
30
350
33
450
45
800
65
1500
65
1500
40
900
NATURAL GAS – G20 20 mbar
1/100 mm
72
97
108
133
135
94
Net
Net
g/h G30
g/h G31
763
750
127
125
167
164
254
250
284
279
138
136
Reduced heat capacity
(W)
350
450
800
1500
1500
900