Cumberland Stove Works MF3700 Operator's Manual page 25

Cumberland stove works mf3700,mf3800 multi fuel parlor stove installation and operation
Hide thumbs Also See for MF3700:
Table of Contents

Advertisement

Problem
Stove Will Not Light
Pot Loading
Problem
Lazy Flame
Smell of Smoke in Room
800-345-6007
Display Status
NORMAL READINg
NO PROOF OF FIRE
PUSH "ON" TO START
NORMAL READINg
Display Status
NORMAL READINg
NORMAL READINg
CumberlandStoveWorks.com
INSTALLATION AND OPERATION MANUAL
Possible causes
Hopper is empty
Plugged firepot
Igniter slipped out of torque arm
Igniter failed
No power to igniter
Igniter failed
Plugged firepot
Poor quality fuel
Firepot misaligned
Possible causes
Poor quality fuel
Firepot and plate require cleaning Clean firepot and plate. Clear all
Firepot misaligned
Fireplate in backwards
Exhaust vent is not sealed
properly
Models MF3700, MF3800
Remedy
Add fuel to hopper
Clean firepot. Clear all holes of
ash or debris.
Push igniter back into place
Test igniter output leads on IM.
Confirm air pump operation.
Replace igniter if needed.
Replace IM
Test igniter output leads on IM.
Confirm air pump operation.
Replace igniter if needed.
Clean firepot. Clear all holes of
ash or debris.
Change fuel supplier/moisture
test corn
Make sure firepot is aligned
properly and that there is no
unburned pellets obstructing
proper alignment of firepot.
Remedy
Change fuel supplier/moisture
test corn
holes of ash or debris.
Make sure firepot is aligned
properly and that there is no
unburned pellets obstructing
proper alignment of firepot.
Adjust fireplate for correct
positioning. Fireplate notches
should always face towards the
front door of the stove.
Seal all joints of exhaust vent
with high-temperature silicone
sealant.