Total Capacity Set Point (Max Capacity) - This
setting is used to program a value that corresponds
to the maximum capacity that can be expected from
a unit before it is completely exhausted. If the unit
reaches this set point an immediate regeneration will
occur . This setting will only appear if a flow meter
is connected to the circuit board. Adjust the value
with the "Up" or "Down" keys. The display will show
the "REGEN" icon and "MAXCAP" for two seconds
and then display the "REGEN" and "GALLONS" or
"LITERS" (depending on DIP switch # 7 setting) icons
and the setting numbers to adjust.
Note: "Maxcap" can not be set lower than "Batch".
Pressing the "Program" key will save the setting and move to the next programming step.
Batch Set Point - This setting is used to set the trip
point for regeneration when in flow meter operation.
It will only appear if a flow meter is connected. The
programmed setting displays the actual set point
to trigger regeneration. The display will show the
"REGEN" icon and "bAtch" for two seconds and then
display the "REGEN" and "GALLONS" or "LITERS"
(depending on dip # 7 setting) icons and the setting
numbers to adjust. Adjust the value with the "Up" or
"Down" keys.
Note: "Batch" can not be set higher than
"Maxcap" .
Pressing the "Program" key will save the setting and exit the programming menu.
Save - This setting is used to save customized outputs.
Selecting "Y" saves customized settings; selecting "N"
recalculates outputs based on current inputs.
Note: This option does not appear if outputs are
unchanged.
Pressing the "Program" key will move to the next
programming step.