AccuSoft
Plus circuit board controls all the softener functions. These settings are
®
®
programmed at the time of installation. The following is a list of all the microprocessor functions
in the event that any of the settings need to be adjusted.
A further description of each programming setting and the corresponding display is outlined
below. For a display that has an icon that is displayed solid for the 2 second time period prior
to bringing up the settings, the settings menu can be reached prior to the two second time out by
pressing the "Up" or "Down" key.
Beeper Setting - This setting is used to turn the
beeper on or off for each key press actuation. The
display will show "bEEP X" where X is either "Y" or
"N". The "Y" or "N" will be toggled with the "Up"
and "Down" keys. Setting the Beep option to "N"
will only disable the beeper for key press actuation.
The beeper will still be active for error and alarm
codes.
Pressing the "Program" key will save the setting and move to the next programming step.
Time of Day - This setting is used to program the
current time of day. When in this step the display will
first show "tod" for two seconds.
After "tod" is displayed, "12:00 PM" will display
(or the current set time if already programmed) and
the minutes will flash. The minutes are adjusted with
the "Up" or "Down" key until the correct value is
displayed.
Press the "Regen" key to flash the hours. Adjust with the "Up" or "Down" key until the
correct time is displayed.
Minutes Flashing
Pressing the "Program" key will save setting and move to the next programming step.
Pressing "Regen" will move back to the minutes adjust.
Time of Regeneration - This setting is used to
program the time at which a regeneration is to occur
in the delay mode, or in immediate mode with time
clock backup on. The display will first show "tor" for
two seconds.
After "tor" is shown the display will then show the
default of 2:00 AM (or the current programmed
time of regeneration if already set). The time can
be adjusted in 30 minute increments by pressing the
"Up" or "Down" keys.
Pressing the "Program" key will save the setting and
move to the next programming step.
Hours Flashing
Time Flashing
Programming
(cont.)