TYPE OF
HOT PLATE
Gas hot plate
ATTENTION!!!
If the power supply cable is replaced, the installer should leave the ground wire (B) longer than the
phase conductors (fig. 15) and comply with the recommendations given in paragraph 8.
FIG. 15

TECHNICAL DATA ON THE DATA LABEL

Category I3
LPG - Butane 5.0 kPa
LPG - Butane 3.0 kPa
Qn
Qn
Voltage = 220 V ~
Frequency = 50/60 Hz
Category I3
LPG - Butane 5.0 kPa
LPG - Butane 3.0 kPa
Qn
Qn
Voltage = 220 V ~
Frequency = 50/60 Hz

SERVICING

CABLE TYPES AND SECTIONS
BURNER ARRANGEMENT ON THE HOT PLATE
- I3B/P
LPG Gas rate =
653 gr/h (5.0 kPa)
LPG Gas rate =
695 gr/h (3.0 kPa)
- I3B/P
LPG Gas rate =
783 gr/h (5.0 kPa)
LPG Gas rate =
822 gr/h (3.0 kPa)
TYPE OF
CABLE
H05 RR - F
In case of failure or cut in the
cable, please move away from
the cable and do not touch it.
Moreover the device must be
unplugged and not switched on.
Call the nearest authorized
service center to fix the problem.