Vfd Parameters - Carrier 48TC 07 Installation, Start-Up And Service Instructions Manual

Variable frequency drive (vfd) factory-installed option 2-speed motor control for 2-stage cooling rooftop units
Hide thumbs Also See for 48TC 07:
Table of Contents

Advertisement

VFD PARAMETERS

The parameters for the VFDs are listed in the following tables
Table 19 — ACS320 VFD common parameters for 48/50
units with electromechanical controls
Table 20 — ACS320 Parameters for 48/50 units with
electromechanical controls
Table 21 — ACS320 VFD common parameters for 48/50
units with I/O Flex controls
Table 22 — ACS320 Parameters for 48/50 units with
I/O Flex controls
Table 23 — ACS320 VFD common parameters for 40RU
units with electromechanical controls
Table 24 — ACS320 Parameters for 40RU units with
electromechanical controls
Table 25 — ACS320 VFD common parameters for 40RU
units with I/O Flex controls
Table 19 — ACS320 VFD Common Parameters for 48/50 Units with Electromechanical Controls
PARAMETERS
9802
9907
1001
1102
1103
1201
1202
1203
1204
1205
1401
1403
1501
1601
1608
1611
2007
2008
2101
2102
2201
2202
2203
2603
2606
3102
3103
3104
5101
5201
5202
5203
5301
5302
5303
5304
5305
LEGEND
— = HVAC Default, field does not require change.
Table 26 — ACS320 Parameters for 40RU units with
I/O Flex controls
Table 27 — ACH550/580 VFD common parameters for
48/50 units with electromechanical controls
Table 28 — ACH550/580 Parameters for 48/50 units with
electromechanical controls
Table 29 — ACH550/580 VFD Parameters for 40RU
Units with VFD Fan Speed Relay Board
Table 30 — ACH550/580 Parameters for 40RU units with
I/O Flex controls
Table 31 — ACH550/580 common parameters for 48/50
units with ComfortLink controls
Table 32 — ACH550/580 Parameters for 48/50 units with
ComfortLink controls
DESCRIPTION
COMM PROT Sel
Motor Nominal Frequency
EXT1 Commands
EXT1/EXT2 Sel
REF 1 Select
Const Speed Sel
Const Speed 1
Const Speed 2
Const Speed 3
Const Speed 4
Relay Output 1
Relay Output 3
AO1 Content Sel
Run Enable
N/A
Parameter View
Minimum Frequency
Maximum Frequency
Start FCN
Stop FCN
ACCEL/DECEL
ACCEL
DECEL
IR COMP Volt
Switching Freq
Trial Time
Delay Time
AR Overcurrent
FBA Type
Station ID
Baud Rate
Parity
EFB Protocol ID
EFB Station ID
EFB Baud Rate
EFB Parity
EFB CTRL Profile
35
SETTING ACS320
Not Selected
60Hz
DI 2,3
40Hz
60Hz
60Hz
(16) FLT/ALARM
Not Selected
3
0.0 HZ
60HZ
(1) Auto
(1) Coast
(0) Not Sel
30s
30s
0 volts
4 HZ
300.0s
6.0s
(1) Enabled