4. PUTTING INTO SERVICE
The machine must be secured to a surface using the "T" bolts provided. Refer to 07535-03000.
The workstation must be mounted in such a way that the working envelope is always above the top of the work bench.
4.1 AIR SUPPLY
All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators
and automatic oiling/filtering systems on the main air supply. To ensure maximum tool life and minimum tool maintenance
they should be fitted within 3 meters of the tool (see diagram below).
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced
in the system or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and
should be armoured where operating conditions may result in hoses being damaged. All air supply hoses MUST have
a minimum bore diameter of 6.4 millimeters or 1/4 inch.
Read daily servicing details page 14.
Follow the steps below when connecting the tool to the intensifier and main air supply:
•
Adjust the height of the horizontal arm and lock in place, so that the nose of the tool is positioned at the desired height
above the application.
•
Push the end of the larger hose from the intensifier on to the quick release connector on the end of the tool.
STOP COCK (USED DURING
MAINTENANCE OF FILTER/
REGULATOR OR LUBRICATION
3 METRES MAXIMUM
LUBRICATOR
UNITS)
TAKE OFF POINT FROM
MAIN SUPPLY
MAIN SUPPLY DRAIN
PRESSURE REGULATOR
AND FILTER (DRAIN
DAILY)
E N G L I S H
POINT
11