1.2

Component names

Component names are as follows.
(j)
Symbol
Name
(a)
Control logic switch
(b)
Voltage/current input switch
(c)
Terminating resistor switch
(d)
Operation panel
(e)
USB mini B connector
(f)
Control circuit terminals (connector)
(g)
Main circuit terminal block
(h)
Wiring cover 1
(i)
Wiring cover 2
(j)
Front cover
(k)
Cooling fan
(l)
Plug-in option connector
*1
Refer to the FR-E800 Instruction Manual (Function).
*2
Refer to the FR-E800 Instruction Manual (Maintenance).
(k)
(d)
(e)
(f)
(g)
(h)
Description
Select the sink logic (SINK) or the source logic (SOURCE).
Select voltage or current for the input via terminal 2.
Select whether or not to use the terminating resistor for RS-485
communication.
Operates and monitors the inverter. The operation panel cannot be
removed from the inverter.
Connector for a personal computer.
Connects cables for the control circuit.
Connects cables for the main circuit.
Remove it for wiring.
When conduits are installed in the knockout holes of this cover, wiring
can be passed through the conduits.
Remove it for wiring.
Cools the inverter (FR-E820-0082(2.2K) or higher, FR-E840-0047(2.2K)
or higher, and FR-E820S-0082(2.2K) or higher).
The fan cover is fixed with the fixing screw(s). When replacing the
cooling fan, remove the fixing screw(s). After replacement, fix the fan
cover with the screw(s).
Not used.
1
2
3
4
(l)
5
(a)
(b)
(c)
6
7
8
(i)
9
10
Refer to page
51
*1
57
*1
59
50
41
24
24
24
*2
15
1. Introduction
1.2 Component names